Evaluation of end-tidal carbon dioxide gradient as a predictor of volume responsiveness in spontaneously breathing healthy adults
Fecha de publicación:
Fecha Ahead of Print:
Autores Icesi
Participantes ajenos a Icesi
- Cordoba, VZ
- Llanos, AMC
- Cristancho, LAB
Resumen
Background: Methods to guide fluid therapy in spontaneously breathing patients are scarce. No studies have reported the accuracy of end-tidal CO2 (ET-CO2) to predict volume responsiveness in these patients. We sought to evaluate the ET-CO2 gradient (Delta ET-CO2) after a passive leg rise (PLR) maneuver to predict volume responsiveness in spontaneously breathing healthy adults. Methods: We conducted a prospective study in healthy adult human volunteers. A PLR maneuver was performed and cardiac output (CO) was measured by transthoracic echocardiography. ET-CO2 was measured with non-invasive capnographs. Volume responsiveness was defined as an increase in cardiac output (CO) > 12% at 90 s after PLR. Results: Of the 50 volunteers, 32% were classified as volume responders. In this group, the left ventricle outflow tract velocity time integral (VTILVOT) increased from 17.9 +/- 3.0 to 20.4 +/- 3.4 (p = 0.0004), CO increased from 4.4 +/- 1.5 to 5.5 +/- 1.6 (p = 0.0), and ET-CO2 rose from 32 +/- 4.84 to 33 +/- 5.07 (p = 0.135). Within the entire population, PLR-induced percentage Delta CO was not correlated with percentage Delta ET-CO2 (R-2 = 0.13; p = 036). The area under the receiver operating curve for the ability of ET-CO2 to discriminate responders from non-responders was of 0.67 +/- 0.09 (95% CI 0.498-0.853). A Delta ET-CO2 >= 2 mmHg had a sensitivity of 50%, specificity of 97.06%, positive likelihood ratio of 17.00, negative likelihood ratio of 0.51, positive predictive value of 88.9%, and negative predictive value of 80.5% for the prediction of fluid responsiveness. Conclusions: Delta ET-CO2 after a PLR has limited utility to discriminate responders from non responders among healthy spontaneously breathing adults.
Datos de la publicación
- ISSN/ISSNe:
- 2197-425X, 2197-425X
- Tipo:
- Article
- Páginas:
- 21-21
- PubMed:
- 30062599
- Enlace a otro recurso:
- www.scopus.com
- Factor de Impacto:
- 0.173 SCImago ℠
- Cuartil:
- Q3 SCImago ℠
Intensive Care Medicine Experimental SPRINGEROPEN
Citas Recibidas en Scopus: 5
Documentos
- No hay documentos
Filiaciones
Keywords
- Capnography; Cardiac output; Doppler echocardiography; Blood volume determination; Hemodynamic monitoring
Cita
Arango MC,Cordoba VZ,Llanos A,Cristancho L. Evaluation of end-tidal carbon dioxide gradient as a predictor of volume responsiveness in spontaneously breathing healthy adults. Intensive Care Med Exp. 2018. 6. (1):p. 21-21.
Portal de investigación