Predictive value of dynamic arterial elastance for vasopressor withdrawal: a systematic review and meta-analysis

Fecha de publicación: Fecha Ahead of Print:

Autores Icesi

Participantes ajenos a Icesi

  • Alvarado-Sánchez J.I.
  • Salazar-Ruiz S.
  • Caicedo-Ruiz J.D.
  • Diaztagle-Fernández J.J.
  • Cárdenas-Bolivar Y.R.
  • Carreño-Hernandez F.L.
  • Mora-Salamanca A.F.
  • Montañez-Nariño A.V.
  • Stozitzky-Ríos M.V.
  • Santacruz-Herrera C.
  • Pinsky M.R.

Unidades de Investigación

Resumen

Background: Dynamic arterial elastance (Eadyn) has been investigated for its ability to predict hypotension during the weaning of vasopressors. Our study focused on assessing Eadyn’s performance in the context of critically ill adult patients admitted to the intensive care unit, regardless of diagnosis. Main body: Our study was conducted in accordance with the Preferred Reported Items for Systematic Reviews and Meta-Analysis checklist. The protocol was registered in PROSPERO (CRD42023421462) on May 26, 2023. We included prospective observational studies from the MEDLINE and Embase databases through May 2023. Five studies involving 183 patients were included in the quantitative analysis. We extracted data related to patient clinical characteristics, and information about Eadyn measurement methods, results, and norepinephrine dose. Most patients (76%) were diagnosed with septic shock, while the remaining patients required norepinephrine for other reasons. The average pressure responsiveness rate was 36.20%. The synthesized results yielded an area under the curve of 0.85, with a sensitivity of 0.87 (95% CI 0.74–0.93), specificity of 0.76 (95% CI 0.68–0.83), and diagnostic odds ratio of 19.07 (95% CI 8.47–42.92). Subgroup analyses indicated no variations in the Eadyn based on norepinephrine dosage, the Eadyn measurement device, or the Eadyn diagnostic cutoff to predict cessation of vasopressor support. Conclusions: Eadyn, evaluated through subgroup analyses, demonstrated good predictive ability for the discontinuation of vasopressor support in critically ill patients. © The Author(s) 2024.

© 2024. The Author(s).

Datos de la publicación

ISSN/ISSNe:
2110-5820, 2110-5820

Annals of Intensive Care  Springer Verlag

Tipo:
Review
Páginas:
108-108
PubMed:
38980442
Enlace a otro recurso:
www.scopus.com
Factor de Impacto:
1.576 SCImago ℠
Cuartil:
Q1 SCImago ℠

Citas Recibidas en Scopus: 8

Documentos

  • No hay documentos

Métricas

Filiaciones mostrar / ocultar

Keywords

  • Blood flow velocity predictive value of tests; Critical care; Fluid therapy; Pulse pressure; Stroke volume; Systematic review

Cita

Compartir