Laser-induced graphene electrochemical sensor for quantitative detection of phytotoxic aluminum ions (Al3+) in soils extracts
Fecha de publicación:
Fecha Ahead of Print:
Autores Icesi
Participantes ajenos a Icesi
- Reyes-Loaiza V.
- De La Roche J.
- Hernandez-Renjifo E.
- Idárraga O.
- Da Silva M.
- Valencia D.P.
- Jaramillo-Botero A.
Unidades de Investigación
Resumen
Aluminum in its Al3+ form is a metal that inhibits plant growth, especially in acidic soils (pH < 5.5). Rapid and accurate quantitative detection of Al3+ in agricultural soils is critical for the timely implementation of remediation strategies. However, detecting metal ions requires time-consuming preparation of samples, using expensive instrumentation and non-portable spectroscopic techniques. As an alternative, electrochemical sensors offer a cost-effective and minimally invasive approach for in situ quantification of metal ions. Here, we developed and validated an electrochemical sensor based on bismuth-modified laser-induced graphene (LIG) electrodes for Al3+ quantitative detection in a range relevant to agriculture (1–300 ppm). Our results show a linear Al3+ detection range of 1.07–300 ppm with a variation coefficient of 5.3%, even in the presence of other metal ions (Pb2+, Cd2+, and Cu2+). The sensor offers a limit of detection (LOD) of 0.34 ppm and a limit of quantification (LOQ) of 1.07 ppm. We compared its accuracy for soil samples with pH < 4.8 to within 89–98% of spectroscopic methods (ICP-OES) and potentiometric titration. This technology's portability, easy to use, and cost-effectiveness make it a promising candidate for in situ quantification and remediation of Al3+ in agricultural soils and other complex matrices. © The Author(s) 2024.
© 2024. The Author(s).
Datos de la publicación
- ISSN/ISSNe:
- 2045-2322, 2045-2322
- Tipo:
- Article
- Páginas:
- 5772-5772
- PubMed:
- 38459204
- Enlace a otro recurso:
- www.scopus.com
- Factor de Impacto:
- 0.874 SCImago ℠
- Cuartil:
- Q1 SCImago ℠
SCIENTIFIC REPORTS Nature Publishing Group
Citas Recibidas en Scopus: 30
Documentos
- No hay documentos
Filiaciones
Keywords
- Aluminum; Bismuth; Electrochemical Techniques; Graphite; Ions; Lasers; Soil; aluminum; bismuth; graphite; ion; chemistry; electrochemical analysis; soil
Cita
Reyes V,De La Roche J,Hernandez E,Idárraga O,Da M,Valencia DP,Ghneim T,Jaramillo A. Laser-induced graphene electrochemical sensor for quantitative detection of phytotoxic aluminum ions (Al3+) in soils extracts. Sci. Rep. 2024. 14. (1):p. 5772-5772. IF:3,998. (1).
Portal de investigación