Device-associated infections in neonatal care units in a middle-income country, 2016–2018
Fecha de publicación:
Fecha Ahead of Print:
Autores Icesi
Participantes ajenos a Icesi
- Torres-Muñoz J.
- Hoyos I.V.
- Murillo J.
- Holguin J.
- López E.
Resumen
Objective: Describe the device-associated infections in the NICUs in Cali – Colombia, a middle-income country, between August 2016 to December 2018. Methods: Observational cross-sectional study evaluating reports of device-associated infections in 10 NICUs in Cali, Colombia, between August 2016 and December 2018. Socio-demographic and microbiological data were obtained from the National Public Health surveillance system, through a specialized notification sheet. The relationship of device-associated infections with several outcomes including birth weight, microorganisms, and mortality was evaluated using OR CI95%, using the logistic regression model. Data processing was performed using the statistical program STATA 16. Results: 226 device-associated infections were reported. The rate of infection with central line-associated bloodstream infections was 2.62 per 1000 days of device use and 2.32 per 1000 days for ventilator-associated pneumonia. This was higher in neonates under 1000 g; 4.59 and 4.10, respectively. 43.4% of the infections were due to gram-negative bacteria and 42.3% were due to gram-positive bacteria. Time from hospitalization to diagnosis of all device-associated infections had a median of 14 days. When compared by weight, infants with a weight lower than 1000 g had a greater chance of death (OR 3.61; 95% CI 1.53–8.49, p = 0.03). Infection by gram-negative bacteria was associated with a greater chance of dying (OR 3.06 CI 95 1.33–7.06, p = 0.008). Conclusions: These results highlight the need to maintain epidemiological surveillance processes in neonatal intensive care units, especially when medical devices are used. © 2023 Sociedade Brasileira de Pediatria
Copyright © 2023 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.
Datos de la publicación
- ISSN/ISSNe:
- 0021-7557, 1678-4782
- Tipo:
- Article
- Páginas:
- 485-491
- PubMed:
- 37148912
- Enlace a otro recurso:
- www.scopus.com
- Factor de Impacto:
- 0.713 SCImago ℠
- Cuartil:
- Q2 SCImago ℠
J PEDIAT-BRAZIL Elsevier Editora Ltda
Citas Recibidas en Scopus: 6
Documentos
- No hay documentos
Filiaciones
Keywords
- Active surveillance; Device-associated infections; Healthcare-associated infections; Late onset neonatal sepsis; Sepsis
Cita
Torres J,Hoyos IV,Murillo J,Holguin J,Dávalos D,López E,Torres S. Device-associated infections in neonatal care units in a middle-income country, 2016–2018. J Pediatr (Rio J). 2023. 99. (5):p. 485-491. IF:2,029. (2).
Portal de investigación