Placenta Accreta Spectrum Prenatal Diagnosis Performance: Are Ultrasound False-positive Results Acceptable in Limited-resources Settings?
Fecha de publicación:
Fecha Ahead of Print:
Autores Icesi
Participantes ajenos a Icesi
- Hidalgo, A
- Padilla, N
- Lopez-Tenorio, J
- Victoria, A
- Rengifo, M
- Mejia, M
- Vergara-Galliadi, ML
- Sinisterra-Diaz, SE
- Maya, J
- Zambrano, MA
Unidades de Investigación
Resumen
Objective The immediate referral of patients with risk factors for placenta accreta spectrum (PAS) to specialized centers is recommended, thus favoring an early diagnosis and an interdisciplinary management. However, diagnostic errors are frequent, even in referral centers (RCs). We sought to evaluate the performance of the prenatal diagnosis for PAS in a Latin American hospital. Methods A retrospective descriptive study including patients referred due to the suspicion of PAS was conducted. Data from the prenatal imaging studies were compared with the final diagnoses (intraoperative and/or histological). Results A total of 162 patients were included in the present study. The median gestational age at the time of the first PAS suspicious ultrasound was 29 weeks, but patients arrived at the PAS RC at 34 weeks. The frequency of false-positive results at referring hospitals was 68.5%. Sixty-nine patients underwent surgery based on the suspicion of PAS at 35 weeks, and there was a 28.9% false-positive rate at the RC. In 93 patients, the diagnosis of PAS was ruled out at the RC, with a 2.1% false-negative frequency. Conclusion The prenatal diagnosis of PAS is better at the RC. However, even in these centers, false-positive results are common; therefore, the intraoperative confirmation of the diagnosis of PAS is essential. © 2022 Georg Thieme Verlag. All rights reserved.
Federação Brasileira de Ginecologia e Obstetrícia. This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/).
Datos de la publicación
- ISSN/ISSNe:
- 0100-7203, 1806-9339
- Tipo:
- Article
- Páginas:
- 838-844
- PubMed:
- 36067797
- Enlace a otro recurso:
- www.scopus.com
- Factor de Impacto:
- 0.295 SCImago ℠
- Cuartil:
- Q3 SCImago ℠
Revista Brasileira de Ginecologia e Obstetricia Medisa Editora
Citas Recibidas en Scopus: 9
Documentos
- No hay documentos
Filiaciones
Keywords
- false positive; operative surgical procedure; placenta accreta; prenatal ultrasonic diagnosis; ultrasonography
Cita
Nieto AJ,Benavides JP,Hidalgo A,Padilla N,Lopez J,Victoria A,Rengifo M,Mejia M,Vergara ML,Sinisterra SE,Maya J,Zambrano MA,Burgos JM. Placenta Accreta Spectrum Prenatal Diagnosis Performance: Are Ultrasound False-positive Results Acceptable in Limited-resources Settings?. Rev. Bras. Ginecol. Obstet. 2022. 44. (09):p. 838-844.
Portal de investigación