Hemodynamically unstable non-compressible penetrating torso trauma: a practical surgical approach

Fecha de publicación: Fecha Ahead of Print:

Autores Icesi

Participantes ajenos a Icesi

  • Parra, MW
  • Caicedo, Y
  • Padilla, N
  • Pino, LF
  • Rodriguez-Holguin, F
  • Herrera, MA
  • Quintero, L
  • Hernandez, F
  • Serna, C
  • Hadad, AG

Resumen

Penetrating torso trauma is the second leading cause of death following head injury. Traffic accidents, falls and overall blunt trauma are the most common mechanism of injuries in developed countries; whereas, penetrating trauma which includes gunshot and stabs wounds is more prevalent in developing countries due to ongoing violence and social unrest. Penetrating chest and abdominal trauma have high mortality rates at the scene of the incident when important structures such as the heart, great vessels, or liver are involved. Current controversies surround the optimal surgical approach of these cases including the use of an endovascular device such as the Resuscitative Endovascular Balloon Occlusion of the Aorta (REBOA) and the timing of additional imaging aids. This article aims to shed light on this subject based on the experience earned during the past 30 years in trauma critical care management of the severely injured patient. We have found that prioritizing the fact that the patient is hemodynamically unstable and obtaining early open or endovascular occlusion of the aorta to gain ground on avoiding the development of the lethal diamond is of utmost importance. Damage control surgery starts with choosing the right surgery of the right cavity in the right patient. For this purpose, we present a practical and simple guide on how to perform the surgical approach to penetrating torso trauma in a hemodynamically unstable patient.

Copyright © 2021 Colombia Medica.

Datos de la publicación

ISSN/ISSNe:
1657-9534, 0120-8322

COLOMBIA MÉDICA  Editorial Medica del Valle

Tipo:
Article
Páginas:
-
PubMed:
34188320
Enlace a otro recurso:
www.scopus.com
Factor de Impacto:
0.383 SCImago ℠
Cuartil:
Q3 SCImago ℠

Citas Recibidas en Web of Science: 1

Citas Recibidas en Scopus: 2

Documentos

  • No hay documentos

Métricas

Filiaciones mostrar / ocultar

Keywords

  • Aortic occlusion; Damage control surgery; Hemodynamically unstable non-compressible penetrating torso trauma; Median sternotomy; REBOA

Proyectos de investigación asociados

SISTEMA DE INFORMACION EN TRAUMA: Registro internacional de trauma.

Investigador Principal: Marisol Badiel Ocampo

CA051321 . 2012

Cita

Compartir